FCR Capsula X Imaging Systems

1400000 INR/Piece

Product Details:

X

FCR Capsula X Imaging Systems Price And Quantity

  • 1 Unit
  • 1400000 INR/Piece

FCR Capsula X Imaging Systems Trade Information

  • Letter of Credit (L/C) Letter of Credit at Sight (Sight L/C) Telegraphic Transfer (T/T) Cash in Advance (CID) Cheque Cash Advance (CA)
  • 1 Unit Per Day
  • 7 Days
  • Yes
  • Sample costs shipping and taxes has to be paid by the buyer
  • All India

Product Description

Features:

  • Rigid design

  • Smooth edges

  • Optimum strength

  • Durability


Standard Components
  • FCR capsula X image reader (Model: CR-IR 357)
  • AC power coad
Other system components
  • IP cassette type CC, LC
  • CR console
  • Image recorder: Drypix 1000/300/4000/7000

SuppliesImaging Plate
ST-VI


14" x 17" , 14" x 14", 10" x 12", 8" x 10", 15 x 30cm (Inch settings)
35 x 43 cm, 35 x 35cm, 24 x 30cm, 18 x 24 cm, 15 x 30 cm (Metric settings)

IP Cassette Type CC


14" x 17" (35.4 x 43 cm), 14" x 14" (35.4 x 35.4 cm), 10" x 12", 8" x 10", 24 x 30cm, 18 x 24 cm, 15 x 30cm

Type LC


35.4 x 124.5cm, 35.4 x 101.7 cm, 35.4 x 83 cm, 25.2 x 58 cm, 24 x 57cm

Time Required for IP Feed / Load

IP Type
Required Time
14" x 17" (35 x 43 cm) Approx. 82 sec.
14" x 14" (35 x 43 cm) Approx. 72 sec.
10" x 12"
Approx. 66 sec.
8" x 10"
Approx. 53 sec.
24 x 30 cm
Approx. 66 sec.
18 x 24 cm
Approx. 50 sec.
15 x 30 cm
Approx. 65 sec.

  • The time required for changing the cassette is assumed to be 0 (zero) seconds.
  • The time required for image erasure is assumed to be for exposure performed at 25mR of X-ray dose.
Processing Capacity
IP Type
When connected to
Drypix 7000/CR Console Pluse
14" x 17" (35 x 43 cm)
Approx. 43 IPs/hr.
14" x 14" (35 x 35 cm) Approx. 50 IPs/hr.
10" x 12"
Approx. 54 IPs/hr.
8" x 10"
Approx. 67 IPs/hr.
24 x 30 cm (ST)
Approx. 54 IPs/hr.
18 x 24 cm (ST)
Approx. 72 IPs/hr.
15 x 30 cm (ST)
Approx. 55 IPs/hr.

  • The time required for changing the cassette is assumed to be 0 (zero) seconds
  • The time required for image erasure is assumed to be for exposure performed at 25 mR of X-ray dose.
Time to print on Drypix 7000 through network via CR Console
Approx. 135 sec. (35 x 43 cm).

Time To Display on CR Console
  • 35 x 43 cm: Approx. 52 sec.
  • 18 x 24 cm: Approx. 31 sec.
  • Number of Stackers: 1
  • Reading gray scale: 12 bits
  • Network: 10 Base T /100 Base TX
  • Dimensions (W x D x H): 590 x 380 x 810 mm (23" x 15" x 32")
  • Weight: 99 kg (218 Ibs.)
  • Power Supply Conditions
    • Single phase 50-60Hz
    • 120-240V ±10%
    • 5A (max).
Environmental Conditions
  • Operating Conditions
    • Temperature: 16-30°C
    • Humidity: 15-80%RH (No dew condensation)
  • Non-operating conditions
    • Temperature: 0.45°C
    • Humidity: 10-90%RH (No dew condensation).