Call Us: +919867260273

FCR Capsula X Imaging Systems

FCR Capsula X Imaging Systems

Product Details:

  • Supply Ability : 1 Unit Per Day
1400000 INR/Piece
X

Price And Quantity

  • 1 Unit
  • 1400000 INR/Piece

Trade Information

  • Telegraphic Transfer (T/T), Letter of Credit at Sight (Sight L/C), Letter of Credit (L/C), Cheque, Cash in Advance (CID), Cash Advance (CA)
  • 1 Unit Per Day
  • 7 Days
  • Yes
  • Sample costs shipping and taxes has to be paid by the buyer
  • All India

Product Description


Features:

  • Rigid design

  • Smooth edges

  • Optimum strength

  • Durability



Standard Components
  • FCR capsula X image reader (Model: CR-IR 357)
  • AC power coad
Other system components
  • IP cassette type CC, LC
  • CR console
  • Image recorder: Drypix 1000/300/4000/7000

SuppliesImaging Plate
ST-VI


14" x 17" , 14" x 14", 10" x 12", 8" x 10", 15 x 30cm (Inch settings)
35 x 43 cm, 35 x 35cm, 24 x 30cm, 18 x 24 cm, 15 x 30 cm (Metric settings)

IP Cassette Type CC


14" x 17" (35.4 x 43 cm), 14" x 14" (35.4 x 35.4 cm), 10" x 12", 8" x 10", 24 x 30cm, 18 x 24 cm, 15 x 30cm

Type LC


35.4 x 124.5cm, 35.4 x 101.7 cm, 35.4 x 83 cm, 25.2 x 58 cm, 24 x 57cm

Time Required for IP Feed / Load

IP Type
Required Time
14" x 17" (35 x 43 cm) Approx. 82 sec.
14" x 14" (35 x 43 cm) Approx. 72 sec.
10" x 12"
Approx. 66 sec.
8" x 10"
Approx. 53 sec.
24 x 30 cm
Approx. 66 sec.
18 x 24 cm
Approx. 50 sec.
15 x 30 cm
Approx. 65 sec.

  • The time required for changing the cassette is assumed to be 0 (zero) seconds.
  • The time required for image erasure is assumed to be for exposure performed at 25mR of X-ray dose.
Processing Capacity
IP Type
When connected to
Drypix 7000/CR Console Pluse
14" x 17" (35 x 43 cm)
Approx. 43 IPs/hr.
14" x 14" (35 x 35 cm) Approx. 50 IPs/hr.
10" x 12"
Approx. 54 IPs/hr.
8" x 10"
Approx. 67 IPs/hr.
24 x 30 cm (ST)
Approx. 54 IPs/hr.
18 x 24 cm (ST)
Approx. 72 IPs/hr.
15 x 30 cm (ST)
Approx. 55 IPs/hr.

  • The time required for changing the cassette is assumed to be 0 (zero) seconds
  • The time required for image erasure is assumed to be for exposure performed at 25 mR of X-ray dose.
Time to print on Drypix 7000 through network via CR Console
Approx. 135 sec. (35 x 43 cm).

Time To Display on CR Console
  • 35 x 43 cm: Approx. 52 sec.
  • 18 x 24 cm: Approx. 31 sec.
  • Number of Stackers: 1
  • Reading gray scale: 12 bits
  • Network: 10 Base T /100 Base TX
  • Dimensions (W x D x H): 590 x 380 x 810 mm (23" x 15" x 32")
  • Weight: 99 kg (218 Ibs.)
  • Power Supply Conditions
    • Single phase 50-60Hz
    • 120-240V 10%
    • 5A (max).
Environmental Conditions
  • Operating Conditions
    • Temperature: 16-30C
    • Humidity: 15-80%RH (No dew condensation)
  • Non-operating conditions
    • Temperature: 0.45C
    • Humidity: 10-90%RH (No dew condensation).

ANITA MEDICAL SYSTEMS PVT. LTD.

* Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.

Other Products in 'Fuji CR Imaging Systems' category



Back to top
ANITA MEDICAL SYSTEMS PVT. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.